Why Chillers Trip on High Head Pressure in Summer

Most summer chiller trips start outside the chiller. Here is how head pressure builds and where to look first.

By B&B Mechanical Team Published

What head pressure is

Head pressure is the refrigerant pressure on the condenser side of the chiller. When the condenser cannot reject heat fast enough, pressure rises and a safety shuts the compressor down to protect it.

The usual causes

  • Condenser water arriving too warm, often because the tower’s approach has widened.
  • Low condenser water flow from a pump, strainer or valve problem.
  • Fouled condenser tubes.
  • Non-condensable gases or refrigerant charge problems.

How the fault is traced

Condenser water temperatures and flow are checked against design, then tower approach, strainers and pump performance. The chiller itself is examined after the loop is ruled out.

Why that order matters

Condemning a chiller for a tower or pump problem is an expensive mistake. Treating the tower, pumps and chiller as one plant is how B&B services water-cooled systems.

A worked diagnosis

Here is how B&B traces a summer trip on a water-cooled chiller in a San Diego office building. Condenser water is arriving warmer than design on a humid afternoon, so the first check is the cooling tower’s approach. If approach has widened, the tower is the cause. If approach is fine but flow is low, the condenser pump, strainer or a valve is the cause. Only when the loop checks out is the chiller’s condenser, charge and non-condensables examined.

What the readings look like

  • Condenser water entering and leaving temperatures against design.
  • Condenser water flow or pressure drop across the bundle.
  • Tower approach and range under the same load.
  • Refrigerant condensing temperature versus leaving water temperature, which exposes fouled tubes.

Preventing the next one

Summer readiness work on the tower, pumps and condenser tubes is what prevents head-pressure trips. For buildings that cannot afford a trip, the maintenance agreement is written to inspect those items before the heat arrives.

Frequently Asked Questions

Is a head pressure trip dangerous to the chiller?

The trip is the protection. Repeated trips mean the cause should be found before the compressor is stressed further.

Can a hot day alone cause it?

Hot, humid weather raises condenser water temperature, which exposes a tower or flow problem that was hidden in milder months.

Does cleaning the condenser tubes help?

Yes when they are fouled. It is part of regular chiller maintenance.

Can the high-pressure setpoint be raised to stop trips?

No. The setpoint protects the compressor; raising it trades a trip for a failure.

Do air-cooled chillers have the same problem?

Yes, with dirty condenser coils or restricted airflow playing the role the tower plays on a water-cooled machine.

Terms used in this guide

Chiller Head Pressure
Head pressure is the refrigerant pressure on the condenser side of a chiller. It rises when the condenser cannot reject heat — warm or low-flow condenser water, fouled tubes or non-condensables — and a high-pressure safety will trip the machine off to protect the compressor.
Water-Cooled Chiller
A water-cooled chiller rejects heat to a condenser water loop served by a cooling tower instead of to outdoor air. It is the central-plant arrangement in larger buildings, pairing the chiller with a tower, condenser water pumps and chilled water pumps.
Condenser Water Pump
The condenser water pump moves water between a chiller's condenser and the cooling tower. It is usually a base-mounted centrifugal pump, and its seals, bearings, impeller and motor are the wear items that decide whether the loop keeps flowing.
Approach Temperature
Approach temperature is the difference between the water leaving a cooling tower and the outdoor wet-bulb temperature, and it's the single best number for tracking a tower's health over time. A tower in good condition holds a fairly consistent approach; a steadily rising approach signals degrading heat transfer.
Cooling Tower Range
Range is the temperature drop across a cooling tower: hot condenser water in minus cooled water out. Range is set by the heat the chiller rejects and the water flow; a collapsing range usually points to a flow problem, not the tower itself.
Have a question?

Talk to a real technician.

Tell us what's going on and our San Diego team will reach out. For emergencies, call us 24/7 at (619) 713-0400.

Call us 24/7(619) 713-0400
  • 24/7 Emergency Service
  • Licensed & Insured
  • 5.0★ Rated on Google
  • Based in Lakeside, CA

10031 Maine Ave, Lakeside, CA 92040

Request a quote

Request your service

No obligation. We never sell your info.

Request Service

Tell us what's going on and our San Diego team will reach out. For emergencies, call us 24/7 at (619) 713-0400.

Loading form. If it does not load, please use the other contact options on this page.

By submitting, you agree to our Privacy Policy and Terms & Conditions. If you opt in to texts, message & data rates may apply and you can reply STOP to opt out.

Call Now Request Service