Temporary Cooling During a Chiller or Cooling Tower Outage

Some outages are unavoidable. Temporary equipment keeps an occupied building conditioned while the plant is worked on.

By B&B Mechanical Team Published

When temporary cooling is the answer

When the shutdown window is longer than the building can ride through, a temporary chiller or tower is connected to carry the load. Hospitals, hotels and data-heavy buildings plan for it rather than hope.

What has to be in place

  • Connection points on the loop, ideally installed ahead of time.
  • Power for the temporary unit and space to set it.
  • A sequence for switching over and back without losing flow.
  • Notices to occupants about noise and access.

Planning it into the project

Temporary cooling is part of the project scope and schedule, not an emergency rental. Its cost is weighed against a longer or staged shutdown.

Sizing and placing temporary equipment

Temporary chillers and towers are sized to the load the building must hold during the outage, which is often less than full design. Placement needs power, a flat space, hose runs to the connection points and a plan for noise near occupied areas.

The switchover

The temporary unit is connected and running before the permanent plant is isolated, so the building never sees the gap. Switching back follows commissioning of the new equipment, not the clock.

Buildings where it is standard

  • Hospitals and clinics with procedure schedules.
  • Hotels and resorts in cooling season.
  • Data and telecom rooms, like the server room B&B fitted with Delta Controls.
  • High-rises whose single-cell tower is the whole plant.

Frequently Asked Questions

Can temporary cooling cover a whole high-rise?

It depends on load and connection points; sometimes a staged swap on a multi-cell tower is the better plan.

Who provides the temporary equipment?

Rental providers, coordinated by the mechanical contractor as part of the job.

Does the loop need modification?

Permanent connection points make future outages far simpler and are worth adding during any plant project.

Does temporary cooling need a permit?

Usually not for a short rental connection; electrical hookups and street placement can. B&B confirms per site.

How far ahead must it be booked?

Early enough to align with the equipment delivery and the shutdown window; it is part of the project schedule.

Terms used in this guide

Chiller Head Pressure
Head pressure is the refrigerant pressure on the condenser side of a chiller. It rises when the condenser cannot reject heat — warm or low-flow condenser water, fouled tubes or non-condensables — and a high-pressure safety will trip the machine off to protect the compressor.
Water-Cooled Chiller
A water-cooled chiller rejects heat to a condenser water loop served by a cooling tower instead of to outdoor air. It is the central-plant arrangement in larger buildings, pairing the chiller with a tower, condenser water pumps and chilled water pumps.
Condenser Water Pump
The condenser water pump moves water between a chiller's condenser and the cooling tower. It is usually a base-mounted centrifugal pump, and its seals, bearings, impeller and motor are the wear items that decide whether the loop keeps flowing.
Approach Temperature
Approach temperature is the difference between the water leaving a cooling tower and the outdoor wet-bulb temperature, and it's the single best number for tracking a tower's health over time. A tower in good condition holds a fairly consistent approach; a steadily rising approach signals degrading heat transfer.
Cooling Tower Range
Range is the temperature drop across a cooling tower: hot condenser water in minus cooled water out. Range is set by the heat the chiller rejects and the water flow; a collapsing range usually points to a flow problem, not the tower itself.
Have a question?

Talk to a real technician.

Tell us what's going on and our San Diego team will reach out. For emergencies, call us 24/7 at (619) 713-0400.

Call us 24/7(619) 713-0400
  • 24/7 Emergency Service
  • Licensed & Insured
  • 5.0★ Rated on Google
  • Based in Lakeside, CA

10031 Maine Ave, Lakeside, CA 92040

Request a quote

Request your service

No obligation. We never sell your info.

Request Service

Tell us what's going on and our San Diego team will reach out. For emergencies, call us 24/7 at (619) 713-0400.

Loading form. If it does not load, please use the other contact options on this page.

By submitting, you agree to our Privacy Policy and Terms & Conditions. If you opt in to texts, message & data rates may apply and you can reply STOP to opt out.

Call Now Request Service