Chief & Building Engineers
You know your plant. You want a contractor who can talk approach temperature, head pressure and lockout codes without a sales layer in between. Kyle, our service manager, specializes in large equipment and attends factory training on it.
Diagnostics you can check
We show our readings, explain what points to the fault and separate what must be done now from what can wait for the next shutdown. If the fix is a part and an hour, that is the recommendation.
Large equipment, specifically
- Cooling towers: fill, drives, basins, approach and range.
- Chillers: head pressure, refrigerant charge, condenser water flow.
- Boilers: ignition, flame safeguard, CSD-1 controls, hydronic circulation.
- Pumps and drives: seals, bearings, VFD programming.
Working alongside your team
Many engineers keep routine maintenance in house and call us for the big items. We fit either way, with service reports written for an engineer, not for a brochure.
How we work with an engineer on site
You know the plant's history; we bring readings, parts and the hours. Findings are shared as they are taken, recommendations are separated into now and next shutdown, and your preferences on sequences and setpoints are respected unless they conflict with safety.
Large-equipment specifics
- Cooling towers: approach and range trending, fill condition, drive alignment, basin and isolator inspection.
- Chillers: head pressure versus leaving water temperature, condenser tube condition, charge and non-condensables, safety setpoints left alone.
- Boilers: combustion readings, flame signal, CSD-1 tests, hydronic flow and air.
- Pumps and drives: seal and bearing condition, alignment, amp draw against nameplate, drive parameters.
Controls and BAS
Mechanical changes are coordinated with the building automation system so sequences, setpoints and alarms match the equipment. The Ubiquity server room project included a Delta Controls installation; on existing systems B&B works with the building's controls contractor or in-house programmer.
Readings we take and share
Tower approach and range, chiller head pressure against leaving water temperature, condenser water flow and delta-T, pump amps against nameplate, drive parameters, boiler combustion numbers and flame signal, hydronic pressures and air. Readings are shared as they are taken, not only in the report.
Diagnosing the loop, not the symptom
A chiller trip is usually a tower or condenser water problem; a boiler lockout is usually ignition, flow or air; a pump failure is usually a seal or alignment issue upstream of the motor. B&B traces the system before touching the safety that tripped.
Parts, stock and lead times
Common wear parts for the towers, pumps, drives and boilers we service are carried or sourced quickly; compressors, heat exchangers and specialty controls are ordered with the scope and their lead time stated. The glossary and guides in the Learning Center carry the vocabulary we use on site.
Services for chief & building engineers
Frequently asked questions
- Will you share the readings behind a recommendation?
- Yes. Temperatures, pressures, amp draws and fault codes go in the service report.
- Can you work with our building automation system?
- Yes. The Ubiquity server room project included a Delta Controls installation; we coordinate with the BAS on controls upgrades.
- Can we keep routine maintenance in house and call you for large equipment?
- Yes. Many engineers do exactly that, and the service reports fit alongside the in-house log.
- Will you leave safety setpoints alone?
- Yes. Safety limits protect the equipment; the fix is upstream of the trip, never at the setpoint.
- Will you share raw readings, not just conclusions?
- Yes. The readings go on the service report and are shared on site as they are taken.
- Can you help with a BAS sequence that does not match the equipment?
- Yes. Mechanical findings are coordinated with the building's controls contractor or programmer so the sequence and the equipment agree.
Equipment B&B has installed and serviced, by brand
Each mark links to the project or service page where B&B worked on that equipment. No dealer badges — just the jobs.
-
Cooling towers Pasadena Courtyard tower retrofit ↗
-
Cooling towers Alta cooling tower retrofit ↗
-
Cooling towers Cooling tower service ↗
- Trane Chillers Riviera Resort chiller & tower retrofit ↗
- Carrier Chillers · package units Riviera Resort chiller & tower retrofit ↗
- York Split systems Ubiquity server room ↗
-
Boilers Coronado Shores mechanical pad retrofit ↗
-
Boilers Boiler service ↗
-
Variable frequency drives Medical Facility tower replacement ↗
- Delta Controls Building controls Ubiquity server room ↗
Need commercial mechanical help for chief & building engineers?
Tell us what's going on and our San Diego team will reach out. For emergencies, call us 24/7 at (619) 713-0400.
Call us 24/7(619) 713-0400- 24/7 Emergency Service
- Licensed & Insured
- 5.0★ Rated on Google
- Based in Lakeside, CA
10031 Maine Ave, Lakeside, CA 92040
Request your service
No obligation. We never sell your info.