Evapco
B&B Mechanical services and installs Evapco cooling towers and closed-circuit coolers serving chillers and process loads. We are not a dealer for Evapco; we are the mechanical contractor that keeps this equipment running and replaces it when its time comes.
Where we see Evapco equipment
Evapco cooling towers and closed-circuit coolers serving chillers and process loads show up across the buildings we serve in San Diego County, from high-rise central plants to retail roofs. The makes in this list come from B&B's own job photos and project write-ups, not a catalog.
How we service it
- Diagnose with readings, not guesses: temperatures, pressures, amp draw, fault codes.
- Repair with the right parts when the equipment is sound.
- Recommend replacement when the heat exchanger, structure, compressor or controls are past repair.
- Fold the equipment into a preventative maintenance agreement written to your asset list.
Replacement and retrofit
When a cooling tower is replaced we handle selection, engineering coordination, permits, the crane or rigging plan and commissioning. Matching the existing make is one option; matching the load and the building is the requirement.
Towers and coolers we service
Evapco cooling towers and closed-circuit coolers serve chillers and process loads across the county. We inspect fill and drift eliminators, service drives and basins, trend approach and range, and plan replacements with the chiller load in mind.
Common Evapco service items
- Fill and eliminator cleaning or replacement.
- Spray nozzle and water distribution correction.
- Drive, belt and bearing service; fan balance.
- Basin, strainer and makeup valve service.
- Coil inspection on closed-circuit coolers.
Replacement and selection
Replacement scopes cover survey, engineering coordination, permits, crane and rigging, base and isolators, piping and commissioning. The make of the new unit follows the load and the building, with the existing manufacturer as one option.
Signs an Evapco tower or cooler needs service
- Approach widening on hot afternoons.
- Drift carry-over wetting the roof.
- Uneven water distribution across the fill.
- Fan vibration or bearing noise.
- Chiller head pressure rising late in the day.
What drives the cost of Evapco tower work
Fill, eliminator and drive repairs price around parts and access. Replacement prices around size, crane access, base and isolators, piping and electrical renewal and the shutdown window. Required and recommended items are separated in the scope.
Water treatment and coils
Closed-circuit cooler coils and open-tower fill both depend on the building's water treatment program. Inspections report scale and fouling so the treatment provider can adjust. The Learning Center's cooling tower guides cover the readings.
Services for evapco
Frequently asked questions
- Are you an authorized Evapco dealer?
- No. B&B Mechanical is an independent commercial mechanical contractor that services and installs cooling towers from several manufacturers, including Evapco.
- Can you replace a Evapco unit with a different make?
- Yes. Selection follows the load, the space and the building's controls; staying with the existing manufacturer is one of the options we price.
- What is a closed-circuit cooler?
- A tower that cools process or condenser fluid inside a coil rather than in open contact with air, common where the loop must stay clean.
- Do you service the water treatment on an Evapco tower?
- The building's water treatment provider manages chemistry; B&B's inspections show whether that program is protecting the fill and coils.
- Can an Evapco tower be upsized for a new chiller?
- The tower's capacity is checked against the new load first; where it falls short, replacement or an added cell is scoped.
- Do you service the spray pumps on closed-circuit coolers?
- Yes, as part of tower and cooler maintenance.
Equipment B&B has installed and serviced, by brand
Each mark links to the project or service page where B&B worked on that equipment. No dealer badges — just the jobs.
-
Cooling towers Pasadena Courtyard tower retrofit ↗
-
Cooling towers Alta cooling tower retrofit ↗
-
Cooling towers Cooling tower service ↗
- Trane Chillers Riviera Resort chiller & tower retrofit ↗
- Carrier Chillers · package units Riviera Resort chiller & tower retrofit ↗
- York Split systems Ubiquity server room ↗
-
Boilers Coronado Shores mechanical pad retrofit ↗
-
Boilers Boiler service ↗
-
Variable frequency drives Medical Facility tower replacement ↗
- Delta Controls Building controls Ubiquity server room ↗
Need commercial mechanical help for evapco?
Tell us what's going on and our San Diego team will reach out. For emergencies, call us 24/7 at (619) 713-0400.
Call us 24/7(619) 713-0400- 24/7 Emergency Service
- Licensed & Insured
- 5.0★ Rated on Google
- Based in Lakeside, CA
10031 Maine Ave, Lakeside, CA 92040
Request your service
No obligation. We never sell your info.